Pneumatic solenoid valve troubleshooting methods

Troubleshooting methods for pneumatic solenoid valves
Pneumatic solenoid valves may have various faults during use. The following are common troubleshooting methods for pneumatic solenoid valves.

 

1. Solenoid valve does not work
Loose wiring head or falling wire head
This is one of the common reasons why the solenoid valve does not work. If the wiring head of the solenoid valve is loose or the wire head falls off, the solenoid valve will not be able to get power. At this time, the problem can be solved by tightening the wire head. When checking the wiring head, you need to ensure that the connection is firm and there is no looseness or virtual connection. For example, in some equipment that is often subjected to vibration, such as the pneumatic solenoid valve next to the running compressor, the wiring head may become loose due to vibration, so it is necessary to check the wiring regularly.

 

Burning of solenoid valve coil
Burning of the solenoid valve coil will prevent the solenoid valve from working properly. You can remove the wiring of the solenoid valve and measure it with a multimeter. If it shows an open circuit, it means that the solenoid valve coil is burned out. There are many reasons for the coil to burn out. For example, if the coil is damp, it will cause poor insulation and magnetic leakage, causing the DC in the coil to be too large and burn out, so rainwater should be prevented from entering the solenoid valve. In addition, the coil may be burned if the spring is too hard, the reaction force is too large, the number of coil turns is too small, and the suction force is insufficient. In emergency treatment, if the solenoid valve has a manual button, the manual button on the coil can be turned from the "0" position during normal operation to the "1" position to open the valve, but this is only a temporary measure and the burned coil needs to be replaced later.

 

Solenoid valve stuck
Because the clearance between the sliding valve sleeve and the valve core of the solenoid valve is very small (less than 0.008mm), and it is generally assembled in one piece, it is easy to get stuck when mechanical impurities are brought in or there is too little lubricating oil. When dealing with this situation, a steel wire can be poked into the small hole in the head to make it rebound. The fundamental solution is to remove the solenoid valve, take out the valve core and valve core sleeve, and clean it with CCI4 so that the valve core can move flexibly in the valve sleeve. When disassembling, pay attention to the assembly sequence of each component and the external wiring position so that the reassembly and wiring are correct. Also check whether the oil spray hole of the oil mist device is blocked and whether the lubricating oil is sufficient. For example, in some dusty working environments, such as the solenoid valves in the pneumatic equipment of cement plants, it is easy to get stuck due to dust ingress, so the working environment needs to be properly dust-proofed.

 

2. Leakage failure
Leakage will cause insufficient air pressure, making it difficult to open and close the forced valve. The main reason is that the sealing gasket is damaged or the slide valve is worn, causing several cavities to leak. When dealing with the solenoid valve failure of the switching system, if there is a leak, you should choose an appropriate opportunity and wait until the solenoid valve is de-energized to handle it. If it cannot be handled within a switching gap, the switching system can be paused and handled calmly. For example, in some pneumatic control systems with strict air pressure requirements, such as the solenoid valve of the pneumatic fixture on the automated assembly line, if there is a leak, it may cause the fixture to fail to work properly and affect the entire production process, so it needs to be handled in time.

 

3. Other faults
Slow response of the solenoid valve
It may be caused by the stuck, blocked, and electromagnet failure of the valve components. If the valve components are blocked or stuck, the solenoid pneumatic valve can be disassembled, the valve components can be cleaned, and an appropriate amount of lubricating oil can be applied to ensure the normal operation of the valve components. If the electromagnet fails, you need to check whether the power supply is normal and use a multimeter to check whether the electromagnet is damaged. If it is confirmed to be damaged, the electromagnet needs to be replaced.

 

The solenoid valve makes too much noise when working
This may be caused by loose valve seats, worn valve components, blocked vents, etc. If the valve seat is loose, you need to disassemble the electromagnetic pneumatic valve, adjust the valve seat position, and ensure that the valve seat is stable and closed. If the valve components are worn, you may need to replace the worn components. If the vent is blocked, you need to clean the blockage of the vent.

 

The temperature of the solenoid valve is too high when working
It may be caused by the expansion valve not working, working under too high pressure, and overheating of the electromagnet. If it is working under too high pressure, the problem can be solved by reducing the working pressure to ensure that the electromagnetic pneumatic valve works within the normal temperature range. If the electromagnet is overheated, you need to check the heat dissipation of the electromagnet, such as whether there is poor ventilation and other problems, improve the heat dissipation conditions or replace the overheated electromagnet components.

 