How to prolong the service life of high temperature solenoid valve?

The service life of high-temperature solenoid valves is generally expressed in times. At present, the service life of most solenoid valves in the market is about 10 million times. Better ones may be 20 or 30 million times. Even with the maturity of technology, there are solenoid valves that can reach 100 million times. Is there any way to improve the service life of high temperature solenoid valve in our daily use?


When using high-temperature solenoid valve, we need to pay attention to the working conditions of installing solenoid valve, such as temperature, pressure, etc. In the process of normal use, the maintenance of high-temperature solenoid valve products is also very important. The following contents can effectively prolong the service life of high-temperature solenoid valve.


1. Before installation, the product shall carefully read the operation manual to check whether the product meets the operation requirements. It is recommended that the user unit assign special personnel to be responsible for maintenance.


2. Metal debris, residual raw material belt, rust and other impurities in the pipeline must be completely removed before installation in the pipeline and accessories. For non cleaning media, valves must be installed in front of the filter.


3. During installation, prevent condensate steam and impurities from depositing on the valve. Pay attention not to install the high-temperature solenoid valve at the lowest part of the pipeline to avoid affecting the function.


4. Ensure the normal use of the solenoid valve. After the test, connect the medium for several times, and then officially use it after passing the test.


5. During operation, pay attention to the working pressure before and after the valve. The maximum working pressure shall not exceed the rated pressure. When the minimum working pressure, the working pressure difference of the pipeline must also be greater than the minimum pressure to prevent the action failure of the solenoid valve. When the working pressure exceeds the rated pressure or the maximum working pressure, the system shall stop using or reduce the working pressure.


6. During maintenance, the dirt of the valve shall be cleaned regularly.


7. When the high-temperature solenoid valve should be restarted, the steam, condensate and gas should be eliminated, and try to act several times until it runs normally.