Applicability of explosion-proof solenoid valve
The fluid in the pipeline must be consistent with the medium calibrated in the selected solenoid valve series model.
The temperature of the fluid must be lower than the calibration temperature of the solenoid valve.
The allowable liquid viscosity of the solenoid valve is generally below 20CST, and it should be noted if it is greater than 20CST.
Working pressure difference, when the maximum pipeline pressure difference is less than 0.04MPA, Ningbo Airpack company such as ZS, 2W, ZQDF, ZCM series and other direct-acting and step-by-step direct-acting types should be used; when the minimum working pressure difference is greater than 0.04MPA, it can be used. Use pilot-operated (differential pressure) solenoid valve; the maximum working pressure difference should be less than the maximum calibration pressure of the solenoid valve; generally solenoid valves work in one direction, so pay attention to whether there is a back pressure difference, and install a check valve if any.
When the fluid cleanliness is not high, a filter should be installed in front of the solenoid valve. Generally, the solenoid valve requires good cleanliness for the medium.
Pay attention to the flow aperture and port size; solenoid valves generally have only two switch controls; if conditions permit, please install a bypass pipe for easy maintenance; when there is water hammer, the opening and closing time of the solenoid valve should be customized.
Pay attention to the influence of ambient temperature on the solenoid valve
The power supply current and power consumption should be selected according to the output capacity. The power supply voltage is generally allowed to be about ±10%. It must be noted that the VA value is higher when the AC starts.